The UniMeasure HX Series consists of a family of environmentally sealed cable extension transducers for the measurement of linear position and/or linear velocity.

The HX models are appropriate for hostile environments where exposure to rain, wash down, or submersion in various liquids are concerns. With standard features such as oring seals in all joints, wire rope dust and debris wiper, and rigid two point mounting system,

the HX series is the preferred solution when measurement in an adverse environment is necessary. The units are available in two basic package configurations determined by the overall measurement range.

Thirty ranges from 0-2 inches to 0-2,000 inches are offered. Electrical outputs include ratiometric voltage divider, bridge circuit, 4-20 mA, 0 to 5 or 0 to 10 VDC, ±10 VDC, and quadrature square wave digital. A brief description of each of the series follows.

HX-PA Series - Analog Position
HX-PB Series - Analog Position
Ratiometric output voltage from a precision potentiometer configured in a voltage divider circuit. Requires regulated input voltage up to 25 V maximum.
Precision potentiometer in bridge circuit with integral zero and span controls which facilitate interfacing to a bridge amplifier. Requires regulated input voltage up to 25 V maximum.


Specifications
Specifications
HX-P420 Series - Analog Position
HX-P510 Series - Analog Position
Loop powered 4 to 20 mA current transmitter with adjustable zero and span controls. Input voltage is 12V to 35V depending upon total loop impedance.
Provides a 0 to 10 VDC or 0 to 5 VDC voltage output. Includes adjustable zero and span controls. Requires input voltage of 11 to 35 VDC (unregulated acceptable).


Specifications
Specifications
HX-P1010 Series - Analog Position
HX-EP Series - Digital Position
Provides a -10 VDC to +10 VDC or -5 VDC to +5 VDC voltage output with adjustable zero and span controls. Requires +15V, -15V and Common input. Single input voltages optionally available.
Digital, TTL level, two channel square wave output signal. 5 VDC input voltage. Optional configurations include 8 to 28 VDC, current sinking, push-pull & line driver capability


Specifications
Specifications
HX-V Series - Velocity
HX-VP Series - Velocity/Position
Ratiometric output voltage from a precision potentiometer configured in a voltage divider circuit. Requires regulated input voltage up to 25 V maximum.
Ratiometric output votage from a precision potentiometer configured in a voltage divider circuit. Requires regulated input voltage up to 25 V maximum.