Cold treament for Fruit fly
Cold treatment for fruit fly
For fruit export cold treatment may be required by AQIS:
On-shore Cold Treatment Facility Requirements for Thailand
The cold sterilisation can happen either in a refrigerated container or
in a coolroom. The T-TEC Data loggers are suitable for this use as they
have fixed serial numbers and high accuracy.
The requirements are: 6 units of T-TEC 7-3E Data loggers with display
and sensors long enough to go through the seal into the coolroom are
required. 2 sensors must be in the air: one in the air inlet and one in
the outlet. Four sensors must be in the core of the fruit, in specified
locations.
When the loggers are started, the intended location of each logger must
be entered into the file. In the software the logging may be set to
every 5 minutes. This will give more than one month worth of data. The
alarms may set, so that the logger display can show when the
sterilisation is successfully done.
The printout of graphs or files show serial numbers, locations and
temperature versus time.
|